Leo Global Telecommunication Steel Wireless Tower
LEO provide wireless tower design with below requirements

Applicable Standard and Codes
All towers manufactured and design shall be generally in accordance with latest revision of the following standards except where specifically directed otherwise.
Browse the standards
ANSI
| No. | Code | Description |
|---|---|---|
| 1 | ANSI10-97 | Design of latticed steel transmission structures |
| 2 | ANSI B-182-2 | Bolts, nuts and washers dimensions |
No standards match your search.
ASCE
| No. | Code | Description |
|---|---|---|
| 1 | ASCE Manual 72 | – Load testing a simple structure |
| 2 | ASCE 10-97 | Standard Design of latticed steel transmission structures |
No standards match your search.
ASTM
No standards match your search.
AWS
| No. | Code | Description |
|---|---|---|
| 1 | AWS D1.1 | American Welding Society D1,1/D1,1M structural Welding code- Steel |
No standards match your search.
British Standards
No standards match your search.
Chinese Standards
No standards match your search.
DIN/VDE
| No. | Code | Description |
|---|---|---|
| 1 | DIN VDE 0101 | Isokeraunic Level |
| 2 | VDE 0201 | Climatic and environmental conditions |
| 3 | CVDE 0210 | Minimum safety factors under simultaneous working loads |
No standards match your search.
IEC Standards
Covers design criteria, loading tests, transmission and distribution of electricity, and current ratings.
| No. | Code | Description |
|---|---|---|
| 1 | IEC 60826 | Design criteria of overhead lines |
| 2 | IEC 60652 | Loading tests on overhead line structures |
| 3 | IEC 60050 (151) | International Electro-technical Vocabulary Part 51 Electrical and Magnetic Devices |
| 4 | IEC 60050 (601) | Chapter 601: Generation, transmission and distribution of electricity-General |
| 5 | IEC 60050 (601) | Chapter 601: Generation, transmission and distribution of electricity-Operation |
| 6 | IEC 60059 | IEC standard current ratings |
No standards match your search.
ISO
No standards match your search.